Weight: Help
42 g

Laser air quality PM2.5 sensor. Interfejs UART.

On stock: 9

PLN 139,00
PLN 113,01 w/o VAT
Help
EUR 33,10
EUR 26,91 w/o VAT

Tags: sensor, dust, laser, pm2.5

Plantower PMS5003 is a laser dust sensor. Sensor uses laser light scattering principle to measure value of dust particles suspended in the air. Sensor provides precise and reliable reading of PM2.5 value. If you are looking for PM2.5 and PM10 please look at Nova Fitness SDS011.

Specification:

  • Supply voltage: from 4.5 V to 5.5 V
  • Power consumption (work): below 100 mA
  • Power consumption (standby): below 200 μA
  • Sensitivity:
    • 50% - 0.3 μm
    • 98% - 0.5 μm and larger
  • Resolution: 1 μg/m³
  • Work temperature: od -10 °C do 60 °C
  • Humidity (work): 0-99%
  • Size: 50 x 38 x 21 mm

Set includes:

  • PMS5003 sensor (covered with protective film)
  • Cable

Pinout:

Pin 1 from inside. Pin 8 on the outside. 8-pin connector (1.25mm raster).

Pin Function Description Remarks
1 VCC Supply voltage 5V 4.5 - 5.5V
2 GND Ground
3 SET HIGH or SUSPENDED - work mode
LOW - sleep mode
3.3V logic
4 RXD UART/TTL data recieve 3.3V logic
5 TXD UART/TTL data transmit 3.3V logic
6 Reset LOW to reset 3.3V logic
7 NC Not connected
8 NC Not connected